FEATURES OF AIR EXCHANGE SOLUTIONS IN HIGH-RISE RESIDENTIAL BUILDINGS

dc.contributor.authorN. U. Tashmatov
dc.date.accessioned2025-12-29T11:30:49Z
dc.date.issued2025-08-01
dc.description.abstractThe article discusses the device of independent ventilation ducts from the chamber to the ventilated room and high-rise buildings with a large number of floors. The exchange rate in kitchens and sanitary facilities should be taken according to calculations and determination of the cross-section of the supply and exhaust ventilation ducts in high-rise buildings
dc.formatapplication/pdf
dc.identifier.urihttps://americanjournal.org/index.php/ajtas/article/view/3063
dc.identifier.urihttps://asianeducationindex.com/handle/123456789/17230
dc.language.isoeng
dc.publisherAmerican Journals Publishing
dc.relationhttps://americanjournal.org/index.php/ajtas/article/view/3063/2892
dc.rightshttps://creativecommons.org/licenses/by-nc/4.0
dc.sourceAmerican Journal of Technology and Applied Sciences; Vol. 38 (2025); 7-12
dc.source2832-1766
dc.subjectInfiltration, through ventilation, damper or throttle valve, channel combination, multiplicity, intermediate floor.
dc.titleFEATURES OF AIR EXCHANGE SOLUTIONS IN HIGH-RISE RESIDENTIAL BUILDINGS
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typePeer-reviewed Article

item.page.files

item.page.filesection.original.bundle

pagination.showing.labelpagination.showing.detail
loading.default
thumbnail.default.alt
item.page.filesection.name
tashmatov_2025_features_of_air_exchange_solutions_in_hi.pdf
item.page.filesection.size
463.63 KB
item.page.filesection.format
Adobe Portable Document Format

item.page.collections