Methodology For Inspection Of Elevator Systems After Strong Earthquakes And Their Field Testing Under Dynamic Loads

dc.contributor.authorOlimkhon Khondamir
dc.contributor.authorMirhamidova E’zoza
dc.contributor.authorGiyasov Shaxriyor
dc.date.accessioned2026-01-01T10:47:28Z
dc.date.issued2024-11-16
dc.description.abstractThe study outlines a methodology for inspecting elevators after earthquakes and conducting field tests to assess their dynamic characteristics. The tests are carried out in two stages: sudden load release and vibrational impact. Seismometric equipment is used to measure displacements and accelerations of both the elevator and the building. This method helps identify the impact of building design features on elevator performance and enhances their safety in seismically active regions
dc.formatapplication/pdf
dc.identifier.urihttps://zienjournals.com/index.php/tjet/article/view/5685
dc.identifier.urihttps://asianeducationindex.com/handle/123456789/60925
dc.language.isoeng
dc.publisherZien Journals
dc.relationhttps://zienjournals.com/index.php/tjet/article/view/5685/4638
dc.rightshttps://creativecommons.org/licenses/by-nc/4.0
dc.sourceTexas Journal of Engineering and Technology; Vol. 38 (2024): TJET; 13-15
dc.source2770-4491
dc.subjectelevator
dc.subjectcharacteristics
dc.subjectstages
dc.titleMethodology For Inspection Of Elevator Systems After Strong Earthquakes And Their Field Testing Under Dynamic Loads
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typePeer-reviewed Article

item.page.files

item.page.filesection.original.bundle

pagination.showing.labelpagination.showing.detail
loading.default
thumbnail.default.alt
item.page.filesection.name
khondamir_2024_methodology_for_inspection_of_elevator_s.pdf
item.page.filesection.size
213.27 KB
item.page.filesection.format
Adobe Portable Document Format

item.page.collections