MORPHOLOGICAL ANALYSIS OF THE CONSTRUCTIVE-FUNCTIONAL STRUCTURE OF THE SPRINKLER DEVICE WITH DEFLECTOR NOZZLE

dc.contributor.authorZafarjon Khudayorov
dc.date.accessioned2025-12-29T18:16:35Z
dc.date.issued2024-11-30
dc.description.abstractEach element functions as an independent technical object (TO) performing a specific function and facilitating a specific physical process (FJ). This leads to the emergence of two types of connections between elements and, accordingly, two types of systemic management. These elements have specific functional relationships, forming a constructive-functional structure (CFS). The CFS is built based on the correspondence of the function and structure of TOs. This article presents scientific research on methods for improving the CFS of the sprinkler device.
dc.formatapplication/pdf
dc.identifier.urihttps://webofjournals.com/index.php/4/article/view/2335
dc.identifier.urihttps://asianeducationindex.com/handle/123456789/25324
dc.language.isoeng
dc.publisherWeb of Journals Publishing
dc.relationhttps://webofjournals.com/index.php/4/article/view/2335/2314
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0
dc.sourceWeb of Technology: Multidimensional Research Journal; Vol. 2 No. 11 (2024): WOT; 385-389
dc.source2938-3757
dc.subjectSprinkler device, constructive-functional structure, morphological analysis, technical solution, sprinkler irrigation, deflector nozzle, water pipeline, water pressure.
dc.titleMORPHOLOGICAL ANALYSIS OF THE CONSTRUCTIVE-FUNCTIONAL STRUCTURE OF THE SPRINKLER DEVICE WITH DEFLECTOR NOZZLE
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typePeer-reviewed Article

item.page.files

item.page.filesection.original.bundle

pagination.showing.labelpagination.showing.detail
loading.default
thumbnail.default.alt
item.page.filesection.name
khudayorov_2024_morphological_analysis_of_the_constructi.pdf
item.page.filesection.size
451.47 KB
item.page.filesection.format
Adobe Portable Document Format

item.page.collections